Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the rank-math-pro domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/wwwroot/longweielec.com/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the rocket domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/wwwroot/longweielec.com/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the translatepress-multilingual domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/wwwroot/longweielec.com/wp-includes/functions.php on line 6114
10kHz LCR Meter - Longwei Instruments (HK) Co., Limited

Courriel : sales@longweielec.com

Mesureur LCR 10kHz

Mesureur LCR 10kHz

  • Basé sur un seul microprocesseur, utilisant des techniques avancées de 5 ports et des erreurs corrigées par le microprocesseur.
  • Protection contre les chocs, plage de verrouillage et fonction particulière de remise à zéro.
  • Facile à utiliser, grande stabilité, convient aux essais sur le terrain de production.
Nom du produit : LW-2811C Catégorie : Tag :
Modèle LW-2811C
Paramètres de mesure L, C, R, Q, D
Fréquence de mesure 100Hz, 1Hz, 10kHz±0,02%
Plage de mesure
Paramètres Fréquence Plage de mesure
 L

 

 

100Hz 1μH~9999H
1KHz 0,1μH~999,9H
10KHz 0.01μH~99.99H
C 100Hz 1pF~9999μF
1KHz 0,1pF~999,9μF
10KHz 0,1pF~99,99μF
R 0.1Ω~99.99MΩ
Q 0.001~9999
D 0.0001~9.999
Précision de la mesure
Paramètres Fréquence Précision de la mesure
L 100Hz ±[1μH+0.25%(1+L/200H+2mH/L)](1+1/Q)
1KHz ±[0.1μH+0.25%(1+L/200H+0.2mH/L)](1+1/Q)
10KHz ±[0.01μH+0.5%(1+L/10H+0.04mH/L)](1+1/Q)
C 100Hz ±[1pF+0.25%(1+1000pF/Cx+Cx/1000μF)](1+Dx)
1KHz ±[0.1pF+0.25%(1+100pF/Cx+Cx/100μF)](1+Dx)
10KHz ±[0.01pF+0.5%(1+20pF/Cx+Cx/4μF)](1+Dx)
R ±[1mΩ+0.25%(1+R/2MΩ+2Ω/R)](1+Q)
Q 100Hz, 1KHz ±[0.020+0.15(Qx+1/Qx)%]
10KHz ±[0.020+0.2(Qx+1/Qx)%]
D 100Hz, 1KHz ±0.0010(1+Dx2)
10KHz ±0.0015(1+Dx2)
Autres
Niveau du signal de test 0,3Vrms±10% (vide) @ 1 kHz
Vitesse d'essai 4 à 6 fois par seconde
Température 0℃-40℃
Humidité inférieur à 85% RH
Tension d'alimentation AC198V~242V 50Hz±5%
Consommation électrique moins de 30W
Dimensions 360×320×140mm
Poids 3,5 kg

 

 

TitreDescriptionTailleDate d'ajoutTélécharger
Manuel de l'utilisateur Longwei LCR Version EN211.29 KB25-07-2023 Télécharger