Model | LW-8681 | |
Subject | Symbol | Range |
Resistance | R | 0.1Ω-1MΩ |
Capacitance | C | 10Pf-500μF |
Diode test | D | 0.0V-7.0V |
Conduction | COND | 0.1Ω-50Ω |
Insulation Resistance | IR | 1MΩ-500MΩ |
High voltage (leakage current) | HIPOT | 0.1mA-5mA |
Open Circuit / Short Circuit | O/S | 2kΩ-50kΩ |
Unilateral test | ||
Break and short circuit endpoint judgment | ||
Advanced Function | Programmable continuous test Automatic learning Locate Pin Self-diagnosis Self-correction |
|
Basic accuracy | ±1% | |
Test Scan Mode Auto | Auto / Manual Switchable | |
Measurement Frequency and Signal / Voltage | 100-100kHz, 1VAC | |
Low Voltage Measurement Signal | 5VDC / 50mA max. ±5% | |
High Voltage (Leakage Current) Test | 200-500Vac. ±5% | |
High Voltage (Insulation) Test | 100-1000VDC. ±5% (LW8681FA) | |
Measuring Contact | 128 Pin (56/512 Optional) The positive and negative output of high voltage correction Automatic point-finding terminal |
|
Panel Buttons | System / Quick / Edit | |
I / O Interface | RS-232 Port Printer Port Remote Control Port |
|
Memory | Memory 56 groups of setting | |
Input Power | 115/230Vac 60/50Hz ± 10% Switchable | |
Accessory | Automatic Point Finding Probe Fixture cable User Manual Power Cable Remote Control Cable (Optional) RS-232 Cable (Optional) |
|
Operating Environment | 15℃-35℃. RH<75% | |
Dimensions | 425 x 190 x 350mm | |
Weight | 14kg | |
Cable requirement | 1μF Max. |